[1]蒋东飞,田 洪,牟长河,等.颅内动脉瘤术中破裂后成功栓塞一例[J].介入放射学杂志,2011,(10):786.
 JIANG Dong-fei,TIAN Hong,MOU Chang-he,et al. Successful occlusion of intracranial aneurysm ruptured during the interventional embolization procedure: report of one case[J].journal interventional radiology,2011,(10):786.
点击复制

颅内动脉瘤术中破裂后成功栓塞一例()

PDF下载中关闭

分享到:

《介入放射学杂志》[ISSN:1008-794X/CN:31-1796/R]

卷:
期数:
2011年10期
页码:
786
栏目:
病例报告
出版日期:
2011-10-25

文章信息/Info

Title:

Successful occlusion of intracranial aneurysm ruptured during the interventional embolization procedure: report of one case

作者:
蒋东飞 田 洪 牟长河 宋 川 刘 磊
400020 重庆 解放军第三二四医院神经科
Author(s):

JIANG Dong-fei TIAN Hong MOU Chang-he SONG Chuan LIU Lei.

Department of Neurology, No.324 Hospital of PLA , Chongqing 400020, China (J Intervent Radiol, 2011, 20: 786-787)
关键词:
颅内动脉瘤 术中破裂 栓塞术
分类号:
R743.4
文献标志码:

参考文献/References:

[1] 姜大宇, 董克辛, 曲 波, 等. 颅内动脉瘤血管内治疗的并发症及处理[J]. 中国冶金工业医学杂志, 2008, 25: 65 - 66.
[2] 王文杰, 刘一之. 未破裂颅内动脉瘤的特征与破裂风险相关关系的研究进展[J]. 介入放射学杂志, 2009, 18: 233 - 236.
[3] 何旭英, 段传志, 李铁林, 等. 脑动脉瘤血管内栓塞术中破裂的治疗[J]. 介入放射学杂志, 2007, 16: 132 - 134.

相似文献/References:

[1]吴曦,刘建民,黄清海,等.第一代Matrix弹簧圈治疗颅内动脉瘤的安全性及中长期随访结果分析[J].介入放射学杂志,2008,(06):384.
 WU Xi,LIU Jianmin,HUANG Qinghai,et al.Middle and long-term follow-up of intracranial aneurysms treated with Matrix detachable coils[J].journal interventional radiology,2008,(10):384.
[2]杨志刚,刘建民,许奕,等.新型可回撤自膨胀支架在颅内动脉瘤治疗中的应用[J].介入放射学杂志,2008,(07):459.
 YANG Zhigang,LIU Jianmin,XU Yi,et al.Application of a novel retrievable self-expanding stent in intracranial aneurysm treatment[J].journal interventional radiology,2008,(10):459.
[3]潘奇,刘建民,许奕,等.颈内动脉前壁动脉瘤支架结合弹簧圈栓塞术后再出血:病例报道[J].介入放射学杂志,2008,(08):560.
 PAN Qi,LIU Jianmin,XU Yi,et al.Rebleeding after stenting and coil embolization of an aneurysm in anterior wall of the internal carotid artery[J].journal interventional radiology,2008,(10):560.
[4]白卫星,姜喜锋,李天晓,等.Neuroform自膨式支架结合弹簧圈栓塞颅内宽颈动脉瘤[J].介入放射学杂志,2008,(08):539.
 BAI Weixing,JIANG Xifeng,LI Tianxiao,et al.Treatment of intracranial wide neck aneurysm with neuroform self-expanding stent combined with spring coils[J].journal interventional radiology,2008,(10):539.
[5]张鹤,李明华,方淳,等.3.0T时间飞跃法MRA诊断颅内动脉瘤—与DSA对照[J].介入放射学杂志,2008,(09):618.
 ZHANG He,LI Minghua,FANG Chun,et al.Detection of intracranial aneurysm with time-of-flight MRA at 3.0Tesla:comparison with digital subtraction angiography[J].journal interventional radiology,2008,(10):618.
[6]杨志刚,刘建民.单纯网孔支架植入治疗颅内动脉瘤的研究进展[J].介入放射学杂志,2008,(10):745.
 YANG Zhigang,LIU Jianmin.Simple mesh stent placement for treating intracranial aneurysm:progress in research[J].journal interventional radiology,2008,(10):745.
[7]吴曦,刘建民.第一代Martix可吸收聚合物弹簧圈治疗颅内动脉瘤的研制及应用现状[J].介入放射学杂志,2008,(11):828.
 WU Xi,LIU Jianmin.The present development and status of the first generation of Matrix bioabsorbable poly-meric material coil in the treatment of intracranial aneurysms[J].journal interventional radiology,2008,(10):828.
[8]李强,洪波,刘建民.2009世界神经外科和神经介入大会掠影[J].介入放射学杂志,2010,(02):154.
 LI Qiang,HONG Bo,LIU Jianmin.A glance at Live Interventional Neuroradiology&Neurosurgery Course2009[J].journal interventional radiology,2010,(10):154.
[9]黄海东,赵凯,顾建文,等.新型颅内支架Enterprise结合水解脱弹簧圈栓塞治疗颅内微小宽颈动脉瘤[J].介入放射学杂志,2010,(02):91.
 HUANG Haidong,ZHAO Kai,GU Jianwen,et al.A novel intracranial Enterprise stent together with coils for the treatment of very small intracranial wide-necked aneurysms[J].journal interventional radiology,2010,(10):91.
[10]施万印,李永东,李明华,等.弹簧圈再栓塞或覆膜支架治疗颅内动脉瘤复发[J].介入放射学杂志,2010,(04):269.
 SHI Wanyin,LI YongDong,LI MingHua,et al.Endovascular treatment of recurrent intracranial aneurysms with re-coiling or covered stents[J].journal interventional radiology,2010,(10):269.

备注/Memo

备注/Memo:
收稿日期20110321
更新日期/Last Update: 2011-10-25